Letter Sequence Other |
|---|
TAC:MA3465, (Open) TAC:MA7450, (Open) TAC:MA7554, (Open) TAC:MA7658, (Open) TAC:MB2893, (Approved, Closed) TAC:MB4811, (Approved, Closed) TAC:MB4905, (Open) TAC:MB4960, (Approved, Closed) TAC:MB5700, (Open) TAC:MB5790, (Open) TAC:MB5791, (Open) TAC:MB5792, (Open) TAC:MB5793, (Open) TAC:MB6341, (Open) |
|
MONTHYEARML0203901332002-02-0707 February 2002 Electronic Version of Technical Specifications Project stage: Other ML0205706382002-03-28028 March 2002 Issuance of Amendment Revises the Test Frequency for the Containment Spray Nozzles from Once Per 10 Years to Following Activities That Could Result in Nozzle Blockage Project stage: Approval ML0208805052002-03-28028 March 2002 Tech. Spec. Page for Amendment No. 146, Revising the Test Frequency for the Containment Spray Nozzles from Once Per 10 Years to Following Activities That Could Result in Nozzle Blockage Project stage: Other RS-02-071, Request for Approval of Quality Assurance Program Changes for Exelon Generation Company, LLC, and Amergen Energy Company, LLC, Nuclear Power Plants2002-04-0909 April 2002 Request for Approval of Quality Assurance Program Changes for Exelon Generation Company, LLC, and Amergen Energy Company, LLC, Nuclear Power Plants Project stage: Request ML0210104032002-04-10010 April 2002 July 28, 2000, Oyster Creek Nuclear Generating Station, Meeting on Control Room Habitbility Project stage: Meeting ML0210100092002-04-10010 April 2002 July 28, 2000, Oyster Creek Nuclear Generating Station, Meeting on Control Room Habitability Project stage: Meeting ML0131901392002-04-11011 April 2002 Transmittal of Version 6.71 of Saphire Computer Code Project stage: Other ML0210504862002-04-15015 April 2002 Alternate Source Term for Control Room Project stage: Other ML0212802222002-05-0707 May 2002 Licensing Actions Project stage: Other ML0214003812002-05-16016 May 2002 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML0213702202002-05-17017 May 2002 Request Conference Call Proposed Amendment Project stage: Other ML0214105172002-05-21021 May 2002 E-mail Requesting Information in Order to Respond to Letter from Member of the Public Regarding NMP2 Weld KC-32, UT Inspection Project stage: Other ML0214304642002-05-23023 May 2002 Request Telecon with Exelon Corp., Two Proposed Amendments Project stage: Other ML0213600022002-06-0404 June 2002 License Amendment, Revising the Technical Specifications to Be Consistent with Changes Made to 10 CFR 50.59, Changes, Tests, and Experiments Project stage: Other ML0213600052002-06-0404 June 2002 Biweekly Notice Memo, Notice of Issuance of Amendment 151. Amendment Revises Technical Specifications to Be Consistent with Changes Made to 10 CFR 50.59, Changes, Tests, & Experiments Project stage: Approval ML0216905712002-06-0404 June 2002 Tech Specs for Amendment No. 151 Revising the Tech Specs to Be Consistent with Changes Made to 10CFR 50.59, Changes, Tests and Experiments Project stage: Other ML0216302492002-06-0404 June 2002 Comments on Proposed Amendment Project stage: Other ML0215503852002-06-0404 June 2002 Comments on Proposed Amendment Project stage: Other ML0216301202002-06-10010 June 2002 Draft RAI on Your 04/26/02 Amendment Request Project stage: Draft RAI ML0220405862002-07-11011 July 2002 Response to Request for Additional Information - Technical Specification Change Request No. 308 General Electric Stability Analysis Methodology Project stage: Response to RAI ML0219705332002-07-24024 July 2002 Request for Withholding Information from Public Disclosure, Oyster Creek Nuclear Generating Station Project stage: Withholding Request Acceptance ML0222607982002-08-0101 August 2002 Response to Request for Additional Information - Technical Specification Change Request No. 291, Safety Limit Minimum Critical Power Ratio Project stage: Response to RAI ML0221905092002-08-0505 August 2002 Conference Call Re. 04/26/02 Proposed Amend Project stage: Other ML0222804322002-08-13013 August 2002 Refueling Interlock Amendment Project stage: Other ML0222609462002-08-20020 August 2002 Second Request for Additional Information Regarding Your April 26, 2002, Application for Amendment Project stage: RAI ML0232602272002-08-22022 August 2002 Core Operating Limits Report, Revision 13 Project stage: Other ML0223501682002-08-23023 August 2002 Site Visit to Address Issues Related to Amendment Application of April 26, 2002 Project stage: Other ML0224203602002-08-30030 August 2002 Withholding from Public, Response to Request for Additional Information - Technical Specification Change Request No. 291, Safety Limit Minimum Critical Power Ratio, MB5505 Project stage: RAI ML0225601532002-09-12012 September 2002 Revised Draft RAI Re. Refueling Interlock Project stage: Draft RAI ML0226201832002-09-12012 September 2002 Revised Draft RAI Re. Refueling Interlock Project stage: Draft RAI ML0226600972002-09-12012 September 2002 Response to Request for Additional Information - Technical Specification Change Request No. 308, General Electric Stability Analysis Methodology Project stage: Response to RAI ML0225600192002-09-18018 September 2002 Issuance of Amendment Licensed and Non-Licensed Operating Personnel Training Programs Project stage: Approval ML0226302742002-09-18018 September 2002 Oyster Creek,Tech Spec Pages/Amend 232 Project stage: Other ML0227502492002-09-19019 September 2002 Response to Request for Additional Information Technical Specification Change Request No. 298, Refueling Interlocks Project stage: Response to RAI ML0226005292002-09-24024 September 2002 License Amendment Revision to TSs Change Request - Clarification of Requirements for Licensed Operator Qualifications & Training Project stage: Approval ML0227005082002-09-24024 September 2002 Tech Spec Pages for Amendment No. 154, Revision to TSs Change Request - Clarification of Requirements for Licensed Operator Qualifications & Training Project stage: Approval ML0227005492002-09-26026 September 2002 Tech Spec Pages for Amendment 233 Cycle 19 Safety Limit Minimum Critical Power Ratio Project stage: Other ML0226805692002-09-26026 September 2002 Issuance of License Amendment Cycle 19 Safety Limit Minimum Critical Power Ratio Project stage: Approval ML0228300432002-10-0909 October 2002 Current TAC List Project stage: Other ML0228305512002-10-10010 October 2002 Issuance of License Amendment 234, Refueling Interlocks Project stage: Approval ML0228801072002-10-10010 October 2002 Tech Spec Pages for Amendment 234, Refueling Interlocks Project stage: Other ML0229503812002-10-18018 October 2002 Technical Specification Amendment 235 - 2.3 Limiting Safety System Settings Pages 2.3-1, 2.3-2, 2.3-4, 2.3-5, 2.3-6, 3.1-1, 3.1-7, 3.10-2, 3.10-3, and 3.10-4 Project stage: Other ML0229103652002-10-18018 October 2002 Issuance of Amendment Use of Option II Solution for Reactor Instability Problem Project stage: Approval ML0229101492002-10-18018 October 2002 Relief, Alternative Repair of Control Rod Drive Housing Interface with Reactor Vessel. TAC MB5700 Project stage: Other ML0235101082002-12-17017 December 2002 Acknowledge Receipt of COLR, Rev. 13 Project stage: Other ML0234403002002-12-24024 December 2002 Approval of Proposed Revision 70 of Quality Assurance Topical Report EGC-1A, REV.70 in Accordance with 10 CFR 50.54(a) Requirements for Exelon/Amergen Plants Project stage: Other ML0301600142003-01-15015 January 2003 Unit 1 - Application of 10 CFR 50.30(b) to Licensing Submittals Project stage: Other RS-03-034, Delegation of Authority of Amergen Energy Company, LLC (Amergen) Nuclear Power Plants2003-02-0606 February 2003 Delegation of Authority of Amergen Energy Company, LLC (Amergen) Nuclear Power Plants Project stage: Other ML0305706832003-02-26026 February 2003 Unit No. 1 - Delegation of Authority Project stage: Other ML0306903032003-03-0707 March 2003 Tech Spec Pages for Amendment 236, Relocation of Emergency Diesel Generator Maintenance Inspection Requirements Project stage: Other 2002-06-04
[Table View] |
Current TAC List| ML022830043 |
| Person / Time |
|---|
| Site: |
Oyster Creek |
|---|
| Issue date: |
10/09/2002 |
|---|
| From: |
Tam P NRC/NRR/DLPM/LPD1 |
|---|
| To: |
Hufnagel J Exelon Corp |
|---|
| References |
|---|
| TAC MA3465, TAC MA7450, TAC MA7554, TAC MA7658, TAC MB2893, TAC MB4811, TAC MB4905, TAC MB4960, TAC MB5700, TAC MB5790, TAC MB5791, TAC MB5792, TAC MB5793, TAC MB6341 |
| Download: ML022830043 (3) |
|
Text
From:
Peter Tam To:
INTernet:David.distel@exeloncorp.com; INTernet:John.Hufnagel@exeloncorp.com Date:
10/9/02 4:13PM
Subject:
Oyster Creek Current TAC List John:
Attached please find my current TAC list covering all known NRR work on Oyster Creek. I provide this list, hopefully, to greatly reduce the amount of time we have to spend during the 10/15/02 Exelon/NRC meeting to discuss these issues.
This attached list is provided solely to prepare you for discussion during the meeting. It does not convey an NRC staff position, does not commit the NRC staff to anything that is not in official NRC issuances, and does not formally request information. See you at the meeting.
Peter S. Tam, Senior Project Manager Project Directorate I-1 Division of Licensing Project Management Office of Nuclear Reactor Regulation e-mail: pst@nrc.gov Tel.: 301-415-1451 Mail Envelope Properties (3DA48DD9.190 : 10 : 20510)
Subject:
Oyster Creek Current TAC List Creation Date:
10/9/02 4:13PM From:
Peter Tam Created By:
PST@nrc.gov Recipients Action Date & Time David Transferred 10/09/02 04:13PM distel (INTernet:David.distel@exeloncorp.
John Transferred 10/09/02 04:13PM Hufnagel (INTernet:John.Hufnagel@exelonco Post Office Delivered Route David INTernet:exeloncorp.
com John INTernet:exeloncorp.
com Files Size Date & Time OysterTAC.wpd 4886 10/09/02 03:35PM
MESSAGE 1647 10/09/02 04:13PM Options Auto Delete:
No Expiration Date:
None Notify Recipients:
Yes Priority:
Standard Reply Requested:
No Return Notification:
None Concealed
Subject:
No Security:
Standard To Be Delivered:
Immediate Status Tracking:
Delivered & Opened
Oyster CreeK Active TAC Numbers (As of 10/09/02)
TAC No.
Title Starting Doc.
MA3465 Pilot Program Source Term Evaluation (NUREG-1465) 11/15/99 (We need to discuss approach to close out this review.
AmerGen has not asked for approval to change licensing basis via 10 CFR 50.90. Significant NRC staff effort may still be needed to complete review, though not sure what product to issue at the end.)
MA7450 PM Licensee Interfaces MA7554 PM Regional Interfaces MA7658 PM Headquarters Interfaces MB2893 TSCR 298: Refueling Interlocks 09/11/01 (Expect issuance on 10/10/02.)
MB4811 Amend. to Relocate EDG Maintenance Insp. Req.
04/10/02 (Target 4/03 for completion.)
MB4905 Exelon and AmerGen QA Program Changes 04/09/02 (Target 12/31/02 for completion.)
MB4960 Amend. re. Option II Stability Methodology 04/26/02 (Target completion before startup from current refueling.)
MB5700 Alternative Repair of CRD Penetrations 07/26/02 (Target completion before startup from current refueling.)
MB5790 thru MB5793 Five Reliefs 08/01/02 (Target completion by 4/03.)
MB6341 COLR Rev. 13 08/22/02 (No issuance is expected because no approval is needed.)
- No initiating document. This is a non-closing TAC.