September 6, 2002
Dr. Kenneth D. Bergeron
17 Tierra Monte NE
Albuquerque, NM 87122
SUBJECT:
NRC STAFF RESPONSE TO YOUR SUGGESTIONS TO RISK-INFORM THE
REVIEW OF THE SEQUOYAH AND WATTS BAR TRITIUM PRODUCTION
LICENSE AMENDMENT REQUESTS
Dear Dr. Bergeron:
I am responding to your letters of September 13, 2001, and January 16, 2002, requesting that
we risk-inform our process for reviewing Tennessee Valley Authoritys (TVAs) license
amendment requests to produce tritium at Sequoyah and Watts Bar, and expressing other
safety concerns. We reviewed your written requests and evaluated your concerns expressed
during the November 7, 2001, meeting held at One White Flint North.
As you are aware, RIS-2001-002 Guidance on Risk-Informed Decision Making in License
Amendment Reviews, addresses our process for determining when requests for risk
information are justified as part of our review of a license amendment request. We conducted a
technical assessment of the issues you identified following the guidance in RIS-2001-002. We
were not able to substantiate that there would be a significant increase in risk if the U.S.
Nuclear Regulatory Commission (NRC) approved TVAs amendment requests. However, we
elevated your concerns to the risk informed licensing panel (RILP) even though our staffs
assessment did not identify any issues that would raise questions about TVAs ability to
maintain adequate protection of public health and safety. The RILP convened on July 11, 2002,
and unanimously agreed that gathering additional risk information to evaluate TVAs
amendment requests was not necessary. However, in our July 29, 2002, letter to TVA, we did
ask TVA to send us some risk-informed background information to confirm our decision. In
your email of August 10, 2002, to Mark Padovan of the NRC, you asked for a copy of TVAs
response to the staffs request for information. TVAs August 9, 2002, response is enclosed.
Your letters noted numerous safety concerns. NRC staff considered each of your concerns
against the guidance of RIS-2001-002, but grouped the concerns into the following broad
categories:
historical safety performance of Sequoyah and Watts Bar
postulated increased risk from internal events, external events, and security concerns
stemming from the dual-purpose civilian and military-related uses of the TVA reactors
potential ice condenser plant design vulnerabilities to severe accident conditions, in
particular, under station blackout (SBO) scenarios
other issues, such as NRC's legal authority to issue the amendments, Advisory Committee
on Reactor Safeguards (ACRS) participation in the amendment reviews, and more time for
public comments
K. Bergeron
-2-
The staffs assessment of your concerns is provided below.
Regarding your concerns about TVAs performance, the staff does not use overall plant
performance as a criterion for approving amendment requests. The NRCs reactor oversight
process (ROP) continuously monitors licensee performance to provide assurance that licensees
are operating plants safely and in accordance with the regulations and licensing bases. The
ROP allows for a graded, predictable agency response commensurate with licensee
performance. This can result in agency actions up to and including ordering the plant to shut
down should NRC determine performance to be unacceptable.
The ROP relies on objective performance indicators (PIs) along with risk-informed inspections
using 39 inspection procedures to monitor and evaluate plant performance. As discussed in the
most recent Annual Assessment Letters for Watts Bar and Sequoyah, the results of the PIs and
inspections are in the licensee response band of the ROP Action Matrix. This means that
both plants have acceptable performance that does not require additional oversight beyond the
baseline level of inspection. Plant performance results are available for public view on the
NRCs external website at http://www.nrc.gov/NRR/OVERSIGHT/ASSESS/index.html.
You also expressed concern that Watts Bar may not be capable of operating with a tritium
production core. The staff notes that TVA has successfully demonstrated its ability to irradiate
and handle tritium producing burnable absorber rods (TPBARs). TVA successfully irradiated
32 lead test assemblies for one cycle as part of TPBAR efficacy testing at Watts Bar.
Therefore, the staff does not have any basis to question TVAs capability to manage such a
change.
You postulated several new accident scenarios in your letter of January 16, 2002. In particular,
you were concerned that a TPBAR ejection was not evaluated. Each TPBAR has a threaded
end plug that is connected to a hold-down plate. The TPBAR is also secured in place via a
crimping device as described in TVAs submittal of August 20, 2001. The TPBARs are inserted
into fuel assemblies, similar to traditional burnable poison rod assemblies, and do not contain
fissile material. Immediately above the fuel assemblies containing TPBARs is the upper core
plate and reactor vessel upper internals package. Therefore, the staff does not agree that a
realistic scenario exists for TPBARs to be ejected, or that there is a significant increase in
initiating event transients.
You also noted that you believed it was not an appropriate neutronic practice to offset, by
soluble boron poisoning, additional reactivity from higher fuel enrichment. Changes to the core
design and core reactivity issues will be fully addressed in the staffs safety evaluation.
However, the staff did not identify in its deterministic design basis review any reactivity issues
that would warrant probabilistic treatment of TVAs amendment requests.
You suggested that a potential TPBAR drop accident during the TPBAR consolidation process
was not adequately addressed. You note that the TPBAR drop accident could occur with the
plant at full power. The rod consolidation process is performed in the spent fuel pool and, as
such, does not increase the likelihood of a reactor trip. From a dose perspective, TVA
addressed dropping a TPBAR and NRC staff evaluated it for (1) fuel movement in the reactor
cavity and (2) spent fuel pool operations. All of the fuel rods in an irradiated fuel assembly, and
K. Bergeron
-3-
24 TPBARs, are assumed to rupture, releasing the radionuclides within the fuel-clad gap to the
fuel pool or reactor cavity water. TVAs analyses show the offsite consequences of this event
are well within Title 10, Code of Federal Regulations (10 CFR), Part 100, dose guidelines. A
complete radiological assessment of potentially dropped TPBARs will be addressed in the
staffs safety evaluations.
Previous performance issues with the ice condenser system were also noted in your
January 16, 2002, letter. For example, you noted problems with lower inlet door binding for
both plants. These issues have been corrected, and the staff is not aware of any recent door
failures due to floor upheaval/door binding within the past few years. The lower inlet doors
continue to be tested in accordance with each plants Technical Specifications and are
monitored under several licensee programs, including the regulatory-required 10 CFR 50.65
maintenance rule program. More important, there is no direct nexus between a change in the
core design and any effect on the reliability or availability of the ice condenser system.
Therefore, overall, given no demonstrated significant increase from the baseline core damage
frequency, and no demonstrated significant change in containment systems performance, the
staff could not substantiate that there would be a significant increase in the baseline severe
accident large early release frequency because of tritium production.
In your letters, and during the November 7, 2001, meeting, you noted concerns that safeguards
measures at Sequoyah and Watts Bar may be inadequate once tritium production begins at
these stations, especially in view of the events of September 11, 2001. The NRC and its
licensees have taken a number of actions following the terrorist attack of September 11, 2001,
to increase security at NRC-licensed facilities, including a heightened security stance pursuant
to safeguards advisories. On February 25, 2002, the NRC issued Orders to all commercial
nuclear power plants to implement interim compensatory measures for the current threat
environment. Some of the requirements made mandatory by the Orders formalize the security
measures that NRC licensees had taken in response to NRCs advisory letters. The specific
actions are sensitive, but generally include requirements as follows:
increased patrols
augmented security forces and capabilities
additional security posts
installation of additional physical barriers
checks at greater stand-off distances
enhanced coordination with law enforcement and military authorities
restrictive site access for all personnel
additional security measures pertaining to waterways and the owner-controlled land outside
the plants protected areas
K. Bergeron
-4-
During our meeting of November 7, 2001, you raised a specific terrorist scenario against
Watts Bar. Further, you alluded to this postulated vulnerability in your letter of January 16,
2002. Although the exact scenario you described is not evaluated in the plants Updated Final
Safety Analysis Report (UFSAR), the effects of the scenario had been analyzed for design
basis considerations and are documented in the UFSAR. Under such a scenario, the specific
plant structures and systems of interest to your concern are protected from such a
phenomenon. The analysis used bounding design-basis assumptions and conditions beyond
the nominal conditions that would be present from the scenario that you postulated. This
phenomenon was also evaluated in the licensees individual plant examination (IPE) of external
events submittal. The staff concludes that the outcome of the scenario you postulated during
our meeting and in your letter is not credible.
On the matter of the NUREG/CR-6427, Assessment of the DCH [Direct Containment Heating]
Issue for Plants with Ice Condenser Containments, the staff is in the process of resolving
Generic Safety Issue (GSI)-189, Susceptibility of Ice Condenser Plants and Mark III
Containments to Early Failure from Hydrogen Combustion During a Severe Accident.
Although NUREG/CR-6427 notes a 0.97 conditional containment failure probability (CCFP) for
Sequoyah under SBO conditions, this CCFP value results from assumptions that were
appropriate for resolving the Direct Containment Heating issue and must be used in the correct
context. The NUREG gives no credit for offsite power recovery, and provides no evaluation of
recovery of one of several simultaneously failed emergency diesel generators. The NUREG
also does not reflect plant improvements since the licensees original IPE submittal that reduces
the frequency of SBO and reduces the likelihood of core damage during SBO conditions such
as the following:
maintaining high emergency diesel generator reliability
high-temperature reactor coolant pump seals
modifications to the turbine driven auxiliary feedwater operation procedures
improved emergency operating procedures
More realistic treatment of SBO scenarios would probably reduce the core damage frequency,
containment failure frequency, and CCFP. Also, the tritium amendment requests would not
result in an increase in core damage frequency or large early release frequency above the
current values. The CCFP value, as it stands today, is appropriate for its intended purpose of
resolving the direct containment heating issue and use as a screening value for GSI-189
regulatory backfit analysis.
In summary, the staff evaluated your suggestions and concerns against the special
circumstances criteria noted in RIS-2001-002 and against standards defined in NRC Regulatory
Guide 1.174. The staff was not able to substantiate that there would be a significant increase in
risk of internal or external events because of tritium production. The staff concluded this
primarily because a tritium production core in itself does not:
increase the likelihood of an initiating event
K. Bergeron
-5-
affect the probabilistic risk assessment (PRA) success criteria
affect the functionality, availability, or reliability of equipment and structures necessary to
prevent core damage (Level I PRA) or mitigate core damage effects (Level II PRA)
The staff determined that the only salient issue relevant to Sequoyah and Watts Bar is
GSI-189, which is unaffected by TVAs amendment requests. The Office of Nuclear Regulatory
Research is completing GSI-189 regulatory analysis, and will forward it to Office of Nuclear
Reactor Regulation for final resolution. However, the staff does not believe that approving the
amendment requests depends on resolving GSI-189 for reasons previously noted.
You commented on the NRC's legal authority to issue the amendments in light of 42 USC 7272.
This very issue was analyzed by the Atomic Safety and Licensing Board in the recent
consolidated tritium license amendment proceedings. In a decision issued on July 2, 2002
(LBP-02-14), the Board concluded that Public Law 106-65, section 3134(a), which provides that
the Secretary of Energy shall produce tritium at Watts Bar or Sequoyah, and its legislative
history "clearly show that Congress intended for the NRC to entertain" TVAs tritium license
amendment applications, notwithstanding 42 USC 7272. Thus, there should be no doubt that
the NRC has the legal authority to issue the amendments.
The ACRS determines what involvement it will have reviewing licensing actions. It received
your letter of October 18, 2001, on the subject of allowing tritium production at Watts Bar. The
ACRS has not asked to participate in the review of TVAs amendment requests, but wanted to
be informed of our response to you. Accordingly, we are forwarding a copy of this letter to the
ACRS.
You also suggested that the NRC should allow more than 30 days for public comment on the
staffs proposed no significant hazards consideration determinations. On January 15, 2002,
Mr. David Lochbaum of the Union of Concerned Scientists sent us a letter requesting a 60-day
extension of the public comment period. The letter of January 17, 2002, from the Secretary of
the Commission, denied that request. However, the Secretarys letter said that the NRC staff
would consider additional comments as it received them while reviewing other comments.
Likewise, we continued to assess the information in your letters of September 13, 2001, and
January 16, 2002, and are now responding to your concerns.
K. Bergeron
-6-
We appreciate your comments and suggestions regarding the amendment requests for tritium
production and we hope that our response addresses your concerns. Please feel free to
contact L. Mark Padovan at (301) 415-1423 or me should you have any questions.
Sincerely,
/RA/
Brian W. Sheron, Associate Director
for Project Licensing and Technical Analysis
Office of Nuclear Reactor Regulation
Enclosure: TVA letter to NRC dated 8/9/02
cc: Donald J. Moniak
Community Organizer and SRS Project Coordinator
Blue Ridge Environmental Defense League
PO Box 3487
Aiken, South Carolina 29802
Ms. Ann P. Harris
341 Swing Loop Road
Rockwood, Tennessee 37854
Dr. Gary Drinkard
340 Drinkard Dr.
Spring City, TN 37381
Ms. Vickie G. Davis
TDEC-DOE Oversight Division
761 Emory Valley Road
Oak Ridge, TN 37830-7072
K. Bergeron
-6-
We appreciate your comments and suggestions regarding the amendment requests for tritium
production and we hope that our response addresses your concerns. Please feel free to contact
L. Mark Padovan at (301) 415-1423 or me should you have any questions.
Sincerely,
/RA/
Brian W. Sheron, Associate Director
for Project Licensing and Technical Analysis
Office of Nuclear Reactor Regulation
Enclosure: TVA letter to NRC dated 8/9/02
cc: Donald J. Moniak
Community Organizer and SRS Project Coordinator
Blue Ridge Environmental Defense League
PO Box 3487
Aiken, South Carolina 29802
Ms. Ann P. Harris
341 Swing Loop Road
Rockwood, Tennessee 37854
Dr. Gary Drinkard
340 Drinkard Dr.
Spring City, TN 37381
Ms. Vickie G. Davis
TDEC-DOE Oversight Division
761 Emory Valley Road
Oak Ridge, TN 37830-7072
Distribution:
PUBLIC
P. Fredrickson
M. Rubin
PDII-2 r/f
R. Hernan
M. Padovan
B. Clayton (Hard Copy)
K. Jabbour
J. Zwolinski
H. Berkow
M. Franovich
B. Sheron
D. Harrison
S. Rosenberg
Package: ML022460227
Incoming Ltr dated 09/13/01 ML021210210
Enclosure: ML022261052 Incoming Ltr dated 01/16/02 ML020250010
ADAMS Accession Number: ML022410310
- see prior concurrence
Office
PDII-2/PM
PDII-2/LA
DSSA/SPSB
PDII-2 /SC(A)
D/PDII
Name
MPadovan
BClayton
input dated
KJabbour
HBerkow
Date
9/03/02
9/03/02
8/19/02
9/03/02
9/03/02
Office
OGC*
D/DLPM
NRR/ADPT
Name
SHom
JZwolinski
BSheron
Date
8/29/02
9/05/02
9/05/02
OFFICIAL RECORD COPY