L-03-070, Annual Man-Rem Report for 2002

From kanterella
Jump to navigation Jump to search
Annual Man-Rem Report for 2002
ML031150026
Person / Time
Site: Beaver Valley
Issue date: 04/22/2003
From: Bezilla M
FirstEnergy Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-03-070
Download: ML031150026 (2)


Text

FECIOC FirstEnergy Nuclear Operating Company Beaver Valley Power Station Route 168 PO Box4 Shippingport, PA 15077-0004 Mark B. Bezilla Site Vice President 724-682-5234 Fax: 724-643-8069 April 22, 2003 L-03-070 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001

Subject:

Beaver Valley Power Station, Unit No. 1 and No. 2 BV-1 Docket No. 50-334, License No. DPR-66 BV-2 Docket No. 50-412, License No. NPF-73 Beaver Valley Power Station Annual Man-Rem Report In accordance with Beaver Valley Power Station Unit 1 and Unit 2 Technical Specification 6.9.1, this letter forwards the Annual Man-Rem Report (tabulating number of personnel receiving exposure greater than 100 mrem/year) for year 2002 to the Nuclear Regulatory Commission.

There are no regulatory commitments identified in this document. If you have any questions regarding this submittal, please contact Mr. J. T. Lebda, Supervisor of Nuclear Health Physics Services, at (724) 682-5872.

Sincerely, Mark B. Bez la Attachment c:

Mr. T. G. Colburn, Senior Project Manager Mr. D. M. Kern, Sr. Resident Inspector Mr. H. J. Miller, NRC Region I Administrator I- (.0 "I

b J_

HW FENOC Beaver Valley Power Station Units 1 and 2 ANNUAL REPORT OF THE NUMBER OF PERSONNEL RECEIVING GREATER THAN 100 MREM AND THEIR ASSOCIATED EXPOSURE BY WORK FUNCTION AT BVPS FOR CALENDAR YEAR 2002.

NUMBER OF PERSONNEL TOTAL MAN-REM TATWf)N tI I i ITy I (C(ONTTACTOq I -STATION-UTILITY I CONTRACTORS REACTOR lMainftenance 2.608 0.000 0.499 0.337 0.000 0.090 OPERATIONS.

Operating 5.795 0.000 0.000 0.740 0.000 0.000

-AND Health Physics 5.286 0.000 13.615 0.983 0.000 2.730

SURVEIiLLANCE. Supervisory 0.592 0.000 0.000 0.117 0.000 0.000
Engineering 0.000 0.000 0.000 0.000 0.000 0.000

-ainienance 45.994 0.000 111.005 7.844 0.000 27.268 ROUTlI Operating 0.084 0.000 1.086 0.010 0.000 0 239 Health Physics 1.603 0.000 0.311 0.282 0.000 0.070 MAINTENANCE Supervisory 1.423 0.000 1.000 0.247 0.000 0.277

_._iEngfneering 0.000 0.000 0.997 0.000 0 000 0.584 Malntenance.

0.063 0.000 51.098 0.009 0.000 15.447 INSERVICE Operating 0.406 0.000 0.914 0.041 0.000 0.370

.-ealth t'hySic:

4.739 0.000 3.493 0.970 0.000 0.856 JNSPECTION: Supervisory.

1.985 0.000 0.000 0.421 0.000 0.000

Engineering -

0.000 0.000 0.000 0.000 0.000 0.000 Mainterarice-0.314 0.000 0.030 0.042 0.000 0.007 SPECIA1-:

Operatin:. -

0.000 0.000 0.000 0.000 0.000 0.000

.-.ealth Phys!cs.

0.000 0.000 0.056 0.000 0.000 0.010 0MAtNTEMANCE Super9isory... :

0.000 0.000 0.000 0.000 0.000 0.000 i:angmnrn.

0.000 0.000 0.000 0.000 0.000 0.000 W

T

Maintenance 0.762 0.065 0.094 0.000 0.009 WASTE
Operating 0.919 0.000 0.000 0.102 0.000 0.000
Health Physics 1..262 0.000 0.080 0.197 0.000 0.021
PROCESSING Suopetsry:

0.000 0.000 0.000 0.000 0.000 0.000

.i~jineering 0.000 0.000 0.000 0.000 0.000 0.000 Mainterance:

12.894 0.000 34.302 2.340 0.000 7.663

.Operating 1.160 0.000 3.000 0.153 0.000 0.437 REFUELING:

Health Physics 4.109 0.000 2.444 0.692 0.000 0.356 Supervisory:

0.000 0.000 3.000 0.000 0.000 0.454

.::_-_-:_-_._E.ngjneering.

0.000 0.000 1.003 0.000 0.000 0.811 Maiiteaance 62.636 0.000 197.000 10.166 0.000 50.484 Oitlng.:

8.364 0.000 5.000 1.046 0.000 1.046

-TOTALS:- i ea6thf:h' 17.000 0.000 20.000 3.124 0.000 4.043

-uperva sc s:.

4.000 0.000 4.000 0.785 0.000 0.731 GRAND T AL 0.000 0.000 2__.000° 57.395 GRAND TOTALS 1 92.0001 0.000 228.000

- 15.6211 0.00 ooo57.699