05000272/LER-1982-033, Forwards LER 82-033/03L-0.Detailed Event Analysis Encl

From kanterella
Jump to navigation Jump to search
Forwards LER 82-033/03L-0.Detailed Event Analysis Encl
ML20053E986
Person / Time
Site: Salem PSEG icon.png
Issue date: 05/19/1982
From: Midura H
Public Service Enterprise Group
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20053E987 List:
References
NUDOCS 8206100271
Download: ML20053E986 (3)


LER-1982-033, Forwards LER 82-033/03L-0.Detailed Event Analysis Encl
Event date:
Report date:
2721982033R00 - NRC Website

text

D PSEG PutAc Setvice Electric and Gas Company P.O. Box E Hancocks Bridge, Neu Jersey 08038 Salem Generating Station May 19, 1982 Mr.

R. C. Haynes Regional Administrator USNRC Region 1 631 Park Avenue King of Prussia, Pennsylvania 19406 De a r '4r. Haynes:

LICENSE NO. DPR-70 DOCKET NO. 50-272 REPORTABLE OCCURRENCE 82-033/03L Pursuant to the requirements of Salem Generating Station Unit No. 1, Technical Specifications, Section 6.9.1.9.b, we ar; submitting Licensee Event Report for Reportable Occurrence 82-033/03L.

This report is required within thirty (30) days of the occurrence.

Sincerely yours, h[

6" H.

J.

Midura General Manager -

Salem Operations RF:ks CC:

Distribution 8206100271 820519 P_DR ADOCK 05000272 PDR u

Th-Enam PeoMe

$6#

v,

Report Number:

82-033/03L Report Date :

05-19-82 Occurrence Date:

05-02-82 i

Facility:

Salem Generating Station, Unit 1 Public Service Electric & Gas Company Hancocks Bridge, New Jersey 08038 IDENTIFICATION OF OCCURRENCE:

Axial Flux Difference - Out of the Target Band.

1 j

This report was initiated by Incident Report 82-111.

CONDITIONS PRIOR TO OCCURRENCE:

Mode 1 - Rx Power 89% - Unit Load 1020 MWe DESCRIPTION OF OCCURRENCE:

At 0910 hours0.0105 days <br />0.253 hours <br />0.0015 weeks <br />3.46255e-4 months <br />, May 2, 1982, the No. 13A Travelling Screen High Differential Pressure Trip alarm was received, and the Control Room Operator observed a decreasing condenser vacuum.

A rapid load reduction was commenced to maintain the vacuum.

At 0915 hours0.0106 days <br />0.254 hours <br />0.00151 weeks <br />3.481575e-4 months <br />, the operator observed that the axial flux difference (AFD) was outside the +6,-9% target band, and Action Statement 3.2.1.2.a was entered.

This occurrence constituted operation in a degraded mode in accordance with Technical Specification 6.9.1.9.b.

5 DESIGNATION OF APPARENT CAUSE OF OCCURRENCE:

The high differential pressure was caused by grass and debris which had clogged the travelling screen.

ANALYSIS OF. OCCURRENCE :

Technical Specification 3.2.1.2.a requires:

I With between 50 and 90% of rated thermal power, power operation may continue provided 1)

The indicated AFD has not been outside of the +6,-9% target band for more than 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> penalty deviation cumulative during the previous 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, and 2)

The indicated AFD is within the limits shown on Figure 3.2-1 of the Technical Specifications.

Otherwise, reduce thermal power to less than 50% of rated thermal power within 30 minutes, and reduce the Power Range Neutron Flux - High Trip setpoints to less than or equal j

to 55% of rated thermal power within the next 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

0