05000000/LER-1986-022-02, Partially Deleted LER 86-022-02:on 861018,potential Undetected Access Into Vital Area Discovered.Caused by Use of Incorrect Procedure.Card Reader Replaced & Tested to Ensure Proper Operation

From kanterella
(Redirected from 05000000/LER-1986-022-02)
Jump to navigation Jump to search
Partially Deleted LER 86-022-02:on 861018,potential Undetected Access Into Vital Area Discovered.Caused by Use of Incorrect Procedure.Card Reader Replaced & Tested to Ensure Proper Operation
ML20238E823
Person / Time
Site: 05000000, Millstone
Issue date: 02/20/1987
From: Scace S, Weekley P
NORTHEAST NUCLEAR ENERGY CO., NORTHEAST UTILITIES
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20238E403 List:
References
FOIA-87-410 LER-86-022, LER-86-22, MP-10046, NUDOCS 8709150230
Download: ML20238E823 (4)


LER-1986-022, Partially Deleted LER 86-022-02:on 861018,potential Undetected Access Into Vital Area Discovered.Caused by Use of Incorrect Procedure.Card Reader Replaced & Tested to Ensure Proper Operation
Event date:
Report date:
0001986022R02 - NRC Website

text

.

NdC Fors *Sil UJ. NUCLEAR K80VLATost? CCashaussoas sem APP 20Vf D 0888 8u0 M 1

t.lCENSEE EVENT REPORT (LER)

ExP*ts 08m urv== m ooc., vW.cn m

, Ass =

f Milletone Nuclear Pcuer Statim thit 1 o l 5 l 0 [ o l 012 1415 1 lod 0 (3 e

aw Potential infetecta! Access Into a Vital Area IVENT DATE 18)

L8R NUM88R151 REPOAT Dart in OTHER FACILITits sNvolvt0 m)

WONTM OAY YEAR YtAR s t 0, v

,4

[,

WONTH DAY YEAn F ACluf v hauta DOCKET hutsDt AGE)

M111stme Unit 2

,,,,,,,{,,3,3,6 1l0 1 l8 8

6 8 l6 0l2l2 0l2 0l2 2 l0 8l7 Mil. stone Unit 3 1

,,,,,,,, 4,2 3 t

TMin me oaf is ev uirrio evasv4NT to Tse miovinameWrs on is Cea n <Cn.

.< ia. i.tw.,i riti m,

N moo.

m, m,

,,,,,, y n,,,

N @!sH1HG a

MJet Hil M.734 H2)M n.

1 i nowmm wwa>

X 71.titet w n wnanai N 6L.H1HW) 90.7h.lONO M.7Si.)GHvWMA) gug,yg fa 1, _

""*H2*

.mg.4/

"

  • b H' H"'

" *H2"'"Hsi q

n ownin.,

nn an.

u rsi. igx.i A

LICENSEE CONT ACT FOR TMt8 LI A H21 NAME TELEPHONE NUMBER ARE A CODE Patricia L. Wekley, Security Supervisor 2, 0, 3 4, 4, 4,

, 4, 3, 2, 9 COMPLEf t ONE LINI pon E ACM Coi.spoNENT p AltUma D(sCRietD IN TMis ARPORT 03)

"fgh{AC-P0m,T A Lt P

N R

fA LE

.I CAvst SYSTs u COMPONENT

""gy AC-qag CAvst syf7 E W CCMPONENT y

pp B

I,A

,R, D, R R,4,2,3 s

I A l

, l,

I SUPPLf MtNTAL aEPom7 8KPtCTEO H4)

MONTM DAY YEAR l

Sv8Mt18 TON Yts I,9Pw. wse RK9f CT$O Sygett3310N DAT$l ero Ass, a AC, w,, s a -.. i...

~.,, r~..... em-,,. m e >

At Approximately 0245 on 10/18/86 it was determined that the card reader at a vital area door leading into t 1

1 The discovery was made by a securit officer who foun Th l

l 1

NN i

l j

B709150230 870910 PDR FOIA WILLIAM 87-410 PDR 1

J

4mC Fera e344A U.S NVCLEA2 A5OULAToRV COMu198*0h LICENSEE EVENT REPORT (LER) TEXT CONTINUATION anaovio owe o am-eio.

EXMAts $t31/08 F ACILITY N AME (U

  1. "II "V"8I" EI LimavuMBER($1 PA04 (3' T' *

- " %t,%"

%*n:

Millstcne Nuclear Powe.r Station MCI O 15101010121415 81 6 012l2 012 012 OF gl.

.aXT IF nwre space er W. was seksterW NaC #sym 3 SEA's/ tin Effect of Event T'. potential for unauthorized access to a vital area.

Description of Compensatory Meesures Designation of Apparent Cause Th had failed. This caused false inf ation to be transmitte

'Upon replacement of the card reader he door was retested-and it was eterm d that a m still existed. The computer data base was checked and it was found that ad been programmed incorrect 1v.

Investigation revealed that this was one error when a computer technician utilized the wrong procedure when reprogramming a set of card readers for the Unit 2 Outage.

t Duri est outages the card readers at vital area door

~

en i

the c uter technician attempted to set u That procedurb was used durin th Unit 1 outage. When s

not result in proper logging a g

investigation and correct action resulted in revising the technique and g

procedure. The fact th n was j

overlooked. AP a resul M'

)

Investigation reveals that this condition existed from

/86 to 10/18/86.

i During this time approximately five individuals entere i

All of the individuals in question were fully screened and were eligible for access to the area. This situation was reported as a separate event on 10/23/86 at the request of Pegion 1.

Licensee Event Report Number 86-023 was submitted on this event.

Corrective Action

1.

The card reader o

'as replaced and tested to ensure proper operation 1

i

Ync5

'i'.'

LICENSEE EVENT REPORT (LER) TEXT CONTINUATION C

  • e-ovioo.. w sino.4 m com s.was sacitity mAMS (1) oOCa t ? sovnest a L3)

LIR NUwef R ($a 9A06 (2 Vlam 88 0 W8 Na 6 Pe ace, Millstone Nuclear Powr Station Nt1 o l5 lo jo lo l 2l4l5 81 6 012l2 012 0l3 OF 0l ntu - ~ e w.,=:= : w w woiun 2.

The procedure to set up specific card readers fo

$sbeen revised as follows:

I 3.

a)

All defective keys re being held for reorder v be in cred to ensure we have the If we do not have hen it will not be reordered, but will be classified a and the number will never be reissued.

b)

Written instructions have been implemented that detail the handling of defective keys to ensure compliance with item a) above.

4 A review of the meth4ds used to provide configuration control on the security system was conducted. The results of this review indicate that adecuate which provides control over these types of changes.

This method includes a review by Security Operations. Security I6C, Station Services Engineering and Computer Services. Final approval of modifications is done by the Security Supervisor.

g

-..,... =.,.,....,.....

y cener.i Oitices. seio.n sir.i seriin NORTHEAST UYlLITIES ing cceeq ctsCgt go,e9.=0 Owt

  • Cwww

]

m,,,,,,..ss.c,su ns uc, cc w.m.

P.O. BOX 270 c.c.i..ii.om a cc~*='

HARTFORD, CONNECTICUT 06141-0270 s,

.s, omia i u=.a cwa"'

J

<-#,,,,isi m.a.

.ovc- -

(203) 665-5000 k

L February 20, 1987 MP-10046 Re:

10CFR73.71(c)

U. S. Nuclear Regulatory Commission Document Control Desk Washington, D. C.

20555

Reference:

Docket No. 50-245 Docket No. 50-336 Docket No. 50-423 Licensee Event Report 86-022-02 l

Gentlemen:

l This letter forwards a report of a security related event pursuant to the requirements of 10CFR part 73, paragraph 73.71(c). This revision provides a status of corrective actions taken to date.

Very truly you.rs, NORTHEAST NUCLEAR ENERC" COMPANY phen {E.Scacehc4U ykst St Station Superintendent Millstone Nuclear Power Station SES/PLW:co

Attachment:

Report of Security Event 86-022-02 cc:

Dr. T. E. Murley, Region 1 T. Shedlosky, Resident Inspector T. Rebelewski, Resident Inspector

]

l m am aneiwe.

'1 4

n

[$

l